Touch Controllers Reference Guide80
Note:
If your controller does not support the Unit Type command,
you can use the Unit Type Verify command or the Output Identity and
Output Status commands to obtain information about the controller
type, the firmware revision, and the hardware status.
Table 12. Bit Definition for the Unit Type Command
Bit Serial/SMT3 Status TouchPen Status
0 Reserved. RAM error. Hardware
malfunction.
1 ROM error. Firmware checksum
verification error.
Same.
2 PWM error. Unable to establish
PWM operating range at power-up.
Nonrecoverable error.
Analog-to-digital (A/D) error.
The A/D converter malfunctioned.
3 NOVRAM error. The operating
parameters in the controller
NOVRAM are invalid. Using defaults.
Same.
4 HDW error. The controller hardware
failed (unable to initialize or configure
gate array). Nonrecoverable error.
ASIC error. The Application
Specific Integrated Circuit (ASIC)
failed.
5 Reserved. Reset flag.
1 = A Unit Type command has
not been issued since the last reset.
0 = A Unit Type command has
been issued since the last reset.
6
Cable NOVRAM error
1
. The
linearization data in the cable
NOVRAM is invalid.
Reserved.
7 NOVRAM2 error. The linearization
data in the controller NOVRAM is
invalid.
Same.
1. The cable NOVRAM error will flash the LED until the controller receives the
first valid command from the host.